If the voltage of each cell during charge exceeds 4.5 volts. gas may be generated due to the
dissociation of electrolytes. this may cause the pressure inside the cell to rise, and
the pressure releasevent (safety vent) opens and by which electrolytes leak out.
Also, if the cell voltage drops too low (below 1.0V), the copper collector of the negative electrode begins to dissolve into electrolytes, and the cell's performance deteriorates.
The cell must be used as a battery pack equipped with a protection circuit module that
performs the following functions.